Customization: | Available |
---|---|
After-sales Service: | Online Support/Visit Client′s Plant Site |
Application: | Liquid with Suspended Solids, Liquid |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Components Item | Function and usage |
CIP spray ball | Wash &clean tank inside surface and devices automatic ,which should connect to the CIP machine station |
Vent filter | Filter air to prevent the bacteria into the tank ,also can release the tank inside pressure. |
Temperature sensor (gauge)-optional | Indicate inside tank temperature and PID temperature control with the necessary valve and fittings |
Pressure sensor (gauge) optional | Indicate the inside tank pressure |
PH sensor optional | Indicate the product PH data |
PO2 sensor optional | Indicate the product Oxygen content |
Level sensor (gauge) optional | Indicate the inside tank product level height ,there are have different models :(static) pressure type ,ultrasonic type ,radar type ,glass tube type ,plate sight glass type . |
Load cell optional | Indicate the product weight |
VFD ( inverter ) optional | Control and adjust agitator speed |
Safety valve optional | Release inside tank pressure to protect the tank safety |
Flow meter optional | Indicate the solution inlet and outlet volume |
Sight light | Indicate inside tank bright for watching easily |
Manhole (handhole ) | Charge solid product into tank ,also can be used for maintenance inside tank components. |
Sampling valve optional | Take inside tank products sample for offline checking |
Model Item |
PYG-50 | PYG-200 | PYG-1000 | PYG-2000 | PYG-5000 |
Tank work volume:L | 50 | 200 | 1000 | 2000 | 5000 |
Motor power for high shear emulsifying:Kw | 1.1 | 1.5 | 4.0 | 5.5 | 15 |
Agitator speed for high shear emulsifying :RPM | 0-1440 or 0-2900 | ||||
Motor power propeller type agitator g:Kw | 0.37 | 0.75 | 2.5 | 3.0 | 5.5 |
Agitator speed for propeller type agitator :RPM | 0-150 | ||||
Motor power anchor type agitator g:Kw | 0.55 | 1.5 | 4.0 | 5.5 | 11 |
Agitator speed for anchor type agitator :RPM | 0-45 | ||||
Inside shell pressure MPa | -0.1/0.3 (can be done as client's URS) | ||||
Jacket pressure MPa | 0.3 (can be done as client's URS) | ||||
Jacket heating medium | Steam/hot water | ||||
Jacket type | Single full/limpet coil/dimple jacket /inside coil tube |