Distillation kettle | Effective volume: Effective volume 300L, Steam direct heating, Heat exchange area 5m2. Inside: design pressure: 0.09Mpa, working pressure: normal pressure; design temperature:120ºC, work temperature≤100ºC.Working medium:water; Insulation layer: Material Aluminium silicate, thickness 50mm Drain valve:DN75 |
Demister | Size Φ102×400, clamping band quick connect installation, demister to facilitate cleaning.Meet the GMP requirements. |
Condenser | Vertical condenser.:Heat transfer area is greater than 2.5m2 Pipeline: designed pressure: normal pressure;working pressure: normal Pressure; design temperature: 100ºC, work temperature≤100ºC. Working medium:Secondary steam. Length: Φ25×2; Shell: designed pressure: 0.3Mpa,working pressure: normal pressure; design temperature: 80ºC,work temperature: 15~30ºC. Working medium: cooling water. |