| Components Item | Function and usage |
| CIP spray ball | Wash &clean tank inside surface and devices automatic ,which should connect to the CIP machine station |
| Vent filter | Filter air to prevent the bacteria into the tank ,also can release the tank inside pressure. |
| Temperature sensor (gauge) | Indicate inside tank temperature and PID temperature control with the necessary valve and fittings |
| Pressure sensor (gauge) | Indicate the inside tank pressure |
| PH sensor | Indicate the product PH data |
| PO2 sensor | Indicate the product Oxygen content |
| Level sensor (gauge) | Indicate the inside tank product level height ,there are have different models :(static) pressure type ,ultrasonic type ,radar type ,glass tube type ,plate sight glass type . |
| Load cell | Indicate the product weight |
| VFD ( inverter ) | Control and adjust agitator speed |
| Safety valve | Release inside tank pressure to protect the tank safety |
| Flow meter | Indicate the solution inlet and outlet volume |
| Sight light | Indicate inside tank bright for watching easily |
| Manhole (handhole ) | Charge solid product into tank ,also can be used for maintenance inside tank components. |
| Sampling valve | Take inside tank products sample for offline checking |
| Model | PYGT-50 | PYGT-100 | PYGT-500 | PYGT-1000 | PYGT-6000 | ||||
| Tank work volume:L | 50 | 100 | 500 | 1000 | 6000 | ||||
| Motor power for bottom mounted magnetic agitator :Kw | 0.18 | 0.37 | 1.1 | 2.2 | 5.5 | ||||
| Agitator speed for bottom mounted magnetic agitator :RPM | 0-350 ( for the gear motor connection type ),0-600 (for direct motor connection type ) | ||||||||
| Motor power for top mounted propeller type agitator :Kw | 0.37 | 0.55 | 1.1 | 1.5 | 7.5 | ||||
| Agitator speed for top mounted propeller type agitator :RPM | 0-150 | ||||||||
| Inside shell pressure MPa | -0.1/0.3 (can be done as client's URS) | ||||||||
| Jacket pressure MPa | 0.3 (can be done as client's URS) | ||||||||