• Industrial Disinfection UV Heat Sterilizer Machine for Water Treatment Plant
  • Industrial Disinfection UV Heat Sterilizer Machine for Water Treatment Plant

Industrial Disinfection UV Heat Sterilizer Machine for Water Treatment Plant

After-sales Service: Online Support/Visit Client′s Plant Site
Warranty: 1 Year
Certification: ISO9001, UL, RoHS, CE
Application: Industry
Voltage: Customized
Core Components: Sterilizer
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
PHYC
Feeding
Liquid
Output
Liquid Solution
Heating Model
Steam/Hot Oil/Hot Water/Electrical
OEM
Parameter Customization
Material
304/316L Stainless Steel
Related Words
Stainless Steel UV Lamp Sterlizer Water Treatment
Key Selling Points
UV Lamp Sterlizer Water Treatment
Transport Package
Wooden Case Packaging/According to Customer
Specification
5L -100000L
Trademark
JOSTON
Origin
Wenzhou, China
HS Code
8421219990
Production Capacity
30 Sets/Month

Product Description

    Industrial Disinfection UV Heat Sterilizer Machine For Water Treatment Plant
    Industrial Disinfection UV Heat Sterilizer Machine for Water Treatment Plant
    Product Details
    Total iron content Less than 0.3ppm(0.3mg/L)
    H2S Less than 0.05ppm(0.05mg/L)
    Total suspended matter Less than 10 mg/L
    Manganese content Less than 0.05 mg/L
    Water hardness Less than 120 mg/L
    Chroma Less than 15centigrade
    Water Temp. 5-60Centigrade
    PH value 6.5-8
    Interface type flange or thread
    Flow rate 0.3--1000 ton/hour

    UV sterilizers are used both inside and outside the main 304 # stainless steel,polished body in order to strengthen internal and external UV illumination of high purity quartz assembled, with special ultraviolet lamp treatment, with a strong bactericidal, long life, stable and reliable, the bactericidal effect Rate ≥ 99%, life 8000 hours, has been widely used in medicine, food, beverage, life, electronics and other fields.

    Fields of application
    Reclaimed water recycling
    Devices for secondary water supply of the living community
    Disinfection of the treated municipal sewer
    Disinfection of water for aquiculture and processing
    Disinfection of purified water for shellfish species
    Disinfection of water in aquaria and water tanks
    Disinfection of tap water, purified water and mineral water
    Disinfection of water for the food and beverage industries_
    Disinfection of water for such water recreational facilities as swimming poor, etc. Disinfection of drinking water for residential, office and restaurant buildings, etc. Disinfection of bacteria-free water for pharmacy, cosmetics and other such manufacturing industries
    Disinfection of water for hospitals Water, ships and vessels and submarine vessels as well as field activities
    Disinfection of water for agricultural irrigation
    Disinfection of water for municipal landscapes
    Disinfection of water for the water treatment system of central air conditioning in commercial buildings
    Disinfection of cooling water for various large power stations
    Disinfection of drinking water for commercial planes and large passenger planes Disinfection of water for large poultry and livestock farms
    Disinfection of water for small domestic drinking machine
    Greenhouse seedling culture Aquaculture
    Water for municipal landscapes
    Disinfection of water for hospitals
    Food and beverage

    Principle for UV sterilization
    All forms of life known on the earth exist on the basis of DNA and RNA for reproduction and existence. DNA and RNA are both composed of 4 kinds of chemical substance units.
    A--Adenine
    T--Thymine
    C--Cytosine
    G--Guanine (the basic component for the nucleic acid)
    In time of cell reproduction, the long chains inside DNA are opened when Unit A in each chain will look for and connect with Unit T. Each long chain can reproduce an identical chain to the chain freshly split, restore the complete DNA before splitting and serve as the foundation for the new-borne cells. However, the ultraviolet at a wave length of 240-270nm is able to break the capacity of DNA to produced protein and reproduction. Once the DNA and RNA of bacteria and viruses are damaged, their capacity to produce protein and reproduction are both lost. As the bacteria and viruses usually have a very short life cycle, those will soon perish that cannot reproduce.
    The effective of UV sterilization is often expressed in killing ratio, e.g., 99.9%. Namely, 99.9% of the original bacteria have been killed and only 0.1% exists, or, 1/1 000 has survived. As 1000 is the 3 in 103 or in log, it is habitually to express the killing ratio with 310g. The killing ratio of ultraviolet depends on two factors: 1, ultraviolet intensity (I); and 2, irradiation time (T).

    Advantages of Modern UV C Disinfection)
    The UV C Disinfection Technology has been widely accepted by the world for its superior effect in disinfection on cell viruses and other Factors to be Considered Liquid chlorine disinfection Chlorine dioxide disinfection Ozone disinfection LW disinfection pathogenic agents. UVC water disinfection technology has the following obvious advantages.

    High-efficiency sterilization
    Sterilization of cell viruses with UV C is generally within one second. In comparison, the traditional UV and Cl and Ozone Methods takes 20 min to one hour to match the effect of UVC.

    No secondary pollution
    As the UV-c Technology can be controlled within the scope of killing the bacteria or viruses only and it is unnecessary to add any chemicals, it Operation complexity Simple to middle grade Simple to middle grade will not cause the secondary pollution to the water body and the surround environment. Meanwhile, it will not change any component of the water.

    It makes continuous mass sterilization possible.
    The modern UV-C disinfection equipment can work 24 hours a day and 365 days a year. Except for the general maintenance within the fixed time, the optimum operation condition is the 24-hour continuous operation.

    Operation and maintenance is simple and easy and of low cost.
    With the improvement of UV-C core technology, the UV-C disinfection technology is not only the means of the highest disinfection rate of all the disinfection methods but also the simplest and easiest in operation and maintenance and of the lowest cost, reaching RMB 0.004 Yuan/T of water. Therefore, cost performance ratio is the highest of all the disinfection technologies. It has the high efficiency advantage superior to other sterilization technologies but also is the lowest in cost and expenses for operation and maintenance.

    Safe and Reliable Operation
    In terms of the traditional sterilization technology, like the methods of using the chloride or ozone, the disinfectant itself is highly toxic, flammable and explosive. Application of these substances causes latent threat to the site operators, the surrounding environment and the nearby residents. The modern ultraviolet disinfection system, however, does not bear such potential risks.


    Process flow
    When preparing the pure water or high-purity water, predesalination is often conducted with the reverse osmosis units and the ion exchange process is taken for deep desalination. The ultrafiltration device is adopted to further remove the colloids, microorganisms, bacteria and mechanical particles in the water. The main process flow for preparing the pure water or high-purity water with the ultrafiltration units consists of:
    Raw water Pre-Processing RO Ion exchange Ultraviolet sterilizer
    Ion exchange UltrafiItration User


    Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.
    UV wavelength (nm)
    DOSAGE is the product of intensity & time
    dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter
    (μW-s/cm2)
    Note:1000μW-s/cm2=1mj/cm2(milli-joule/cm2)

    As a general guideline, the following are some typical UV transmission rates (UVT)
     
    City water supplies 850-980‰
    De-ionized or Reverse Osmosis water 950-980‰
    Surface waters(lakes, rivers, etc) 700-900‰
    Ground water(wells) 900-950‰
    Other liquids 10-990‰


    Optimal service condition
    As UV is a short- wavelength light wave, it has low radiant energy and weak penetrating power and can only kill the microorganisms it directly radiates on. Therefore, in order to enhance the bacteria-killing efficiency and ensure the security of drinking water, the incoming water into the sterilizer must meet the following standard, (and if exceeding the following standard, the killing efficiency may be affected).

     
    Total iron content Less than 0.3ppm(0.3mg/L)
    H2S Less than 0.05ppm(0.05mg/L)
    Total suspended matter Less than 10 mg/L
    Manganese content Less than 0.05 mg/L
    Water hardness Less than 120 mg/L
    Chroma Less than 15centigrade
    Water Temp. 5-60Centigrade
    PH value 6.5-8
    Interface type flange or thread

    Industrial Disinfection UV Heat Sterilizer Machine for Water Treatment Plant
    Industrial Disinfection UV Heat Sterilizer Machine for Water Treatment Plant
    Industrial Disinfection UV Heat Sterilizer Machine for Water Treatment Plant
    Industrial Disinfection UV Heat Sterilizer Machine for Water Treatment Plant
    Industrial Disinfection UV Heat Sterilizer Machine for Water Treatment PlantIndustrial Disinfection UV Heat Sterilizer Machine for Water Treatment Plant

     


    Industrial Disinfection UV Heat Sterilizer Machine for Water Treatment Plant

     

    Industrial Disinfection UV Heat Sterilizer Machine for Water Treatment PlantIndustrial Disinfection UV Heat Sterilizer Machine for Water Treatment Plant

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now